SICK DFS60S Pro Safety Encoders

At a glance

  • Encoders for functional safety technology: SIL2 (IEC 61508), SILCL2 (EN 62061), PL d (EN ISO 13849)
  • Electrical interface: 4.5 V ... 32 V, sine/cosine 1 VPP, 1,024 periods
  • Clamping flange or servo flange, blind hollow shaft or through hollow shaft (assembly options with feather key)
  • Universal cable outlet, M23 or M12 male connector, axial or radial
  • Enclosure rating: IP 65
  • Working temperature range: –30°C ... +95°C (depending on type)

Your benefits

  • Certified safety products ensuring the best possible protection for persons, machinery, and systems
  • Easy and practical handling of safety functions with all-in-one solutions from a single source, safety functions with the Flexi Soft drive monitor by SICK: safe stop 1 (SS1), safe stop 2 (SS2), safe operating stop (SOS), safe speed monitoring (SSM), safely limited speed (SLS), safe direction (SDI), safe brake control (SBC)
  • Force fit and tight fit for mechanical reliability
  • Certified safety products instead of standard products reduce the scope of safety engineering
  • Versatile connection options for high levels of flexibility and straightforward implementation
  • Compact installation depth for compatibility with applications in which installation space is limited

Downloads

Are you interested in the above product? Contact us for more information by filling out the contact form below or by calling us at +30 210 2389590-2.